Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Samples:
US$ 2.90/Piece 1 Piece(Min.Order)
| Order Sample
standard packing
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p pictures & photos
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p
US $0.1-2.893 / Piece
Min. Order: 1 Piece
Gold Member Since 2005

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
PID-125 4P
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
RCBO
Poles Number
1
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Overcurrent Protection
Certification
ISO9001-2000, CE, CB, CCC
Customization
Available
Frenquency
50/60Hz
Transport Package
Export Packaging
Specification
carton
Trademark
PEOPLE
Origin
China
HS Code
8536200000
Production Capacity
200000PCS/Month

Packaging & Delivery

Package Size
35.00cm * 25.00cm * 20.00cm
Package Gross Weight
25.000kg
Lead Time
20 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

Application
The items is in comply with standard of IEC61008-1,applying to the circuit of AC 50/60Hz,230V
single phase,400V three phases or below it for industrial and mining enterprise, trade building,
commerce and family. It is mainly used for preventing electric fire and personal casual accident
caused by personal electric shock or leakage of electrified wire net, this is a current operated, fast leakage protector of pure electromagnetic type, which can break off fault circuit rapidly in order to avoid occurrence of accident. The item is precise in structure, less elements, without auxiliary power and high working reliability. The function of the switch won't be influenced by ambient temperature and lightning. The mutual inductor of the item is used to test vector differential value of passing current, and produces a relevant output power and add it to the tripper in secondary winding, if the current of vector differential value of protected circuit of personal electric shock is up to or over leakage operating current, the tripper will act and cut off so that the item will take effect of protection.

Working Principle.
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p
Specification.
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4pPid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p
Wiring Diagram.
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p
Overall and Mounting Dimensions (mm).

 
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p
 
 
 



Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p

· Power consumption is far below the national standard requirement 

· High quality, withstand analysis 

· Perfect appearance, feast for the eyes 

· Longer mechanical and electrical life and better performance, greatly reducing maintenance costs for users

FAQ
Q:  If I am interested in your MCB, when can I receive your quotation and details after sending the enquiry?
A:  All your inquiries will be answered within 8 hours.

Q: Can I get samples before placing an order? Because I really don't know if your company's products are of good quality or not.
A: Certainly! We also believe that sample orders are the best way to prove quality. Welcome to inquire about the products you want

Q: What are your terms of trade?
A: We accept exw, fob, cif, fca, etc.

Q: How long is the delivery time?
A: Sample order usually takes 3-5 working days, formal order usually takes 10-20 days.

Q: how to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming,we'll make a satisfied solution for you whin 3  days


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p pictures & photos
Pid-125 RCBO Residual Current Circuit Breaker/Breaking RCCB 230/400V Short Circuit 30mA 3p+N 4p
US $0.1-2.893 / Piece
Min. Order: 1 Piece
Gold Member Since 2005

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
3007
Year of Establishment
1996-04-03