LEADING SERIES-RDM5 Moulded Case Circuit Breaker
Product Description
RDM5E series electronic molded case circuit breaker. The circuit breaker is applicable to the distribution network with AC 50Hz, rated insulation voltage of 1000V, rated working voltage of 690V and below, and rated working current of 800A and below. It is used to distribute electric energy and protect the line and power supply equipment from overload, short circuits, Undervoltage, and other faults.
RDM5E series Circuit breaker with a rated current of 630A and below. It can also be used to protect the motor. Under normal conditions, the circuit breaker can be used for infrequent line switching and infrequent motor starting.
RDM5E series circuit breaker has the functions of overload long time delay inverse time limit, short circuit short time delay inverse time limit, short circuit short time delay definite time limit, short circuit instantaneous and under voltage protection, which can protect the route and power supply equipment from damage.
The product conforms to IEC60497-2/GB/T14048.2 standard.
Application
1.Selective cooperation with three-section protection: use circuit breaker of category B and other short circuit protection connected in the same circuit. The device has selective coordination under short circuit conditions; Setting of overload long delay inverse time limit, short circuit delay (inverse time limit, definite time limit), short circuit instantaneous, and other protection function parameters;
2. It has three parameter settings of action current and action time, and can be adjusted in 4-10 gears: users can adjust according to the load current requirements; the controller can be set and adjusted, and the corresponding functions can be selected to be closed according to the user's requirements (customized functions, which need to be ordered by the us
er, When specified);
3. Large current instantaneous tripping function: when the circuit breaker is closed and running, in case of a short circuit large current ( 20 Inm), the magnetic tripping mechanism of the circuit breaker can directly trip, and the double protection is more reliable and safe;
4. With tripping test (test) function: input DC 12V voltage to test the action characteristics of a circuit breaker;
5. Fault self-diagnosis function: protect and detect the working state and operation of the intelligent controller itself;
6. With pre-alarm indication and overload indication: when the load current reaches or exceeds the setting value, the light guide column will lead out the light source;
7. Dual air gap technology of magnetic flux converter: more reliable and stable operation, no misoperation, reliable tripping, and low power;
8.High protection accuracy: overload protection, short circuit short delay protection action current accuracy ± 10%; The accuracy of short-circuit instantaneous protection value is ± 15% depending
on the action current;
9. Interchangeability of installation: the overall dimensions and installation dimensions are the same as those of the RDM1 series plastic case circuit breaker.
10. Dual passive signal output function: for signal (or alarm), with a capacity of AC230V3A;
11. With fire shunt function: overload alarm does not trip (a pair of passive contacts are provided) and shunt trip function is provided;
12. Communication function: standard RS485, Modbus field bus protocol;
Main technique parameter
Rated current of shell frame grade Inm (A) | 125 | 250 | 400 | 800 |
Rated current In (A) | 32,63,125 | 250 | 400 | 630,800 |
Current setting value IR (A) | (12.5~125)+Close | (100~250)+Close | (160~400)+Close | (250~800)+Close |
Breaking capacity level | M | H | M | H | M | H | M | H |
Number of poles | 3P,4P |
Rated frequency (Hz) | 50 |
Rated insulation voltage Ui (V) | AC1000 |
Rated impulse withstand voltage Uimp (V) | 12000 |
Rated working voltage Ue (V) | AC400/AC690 |
Arcing distance (mm) | ≤50 | ≤50 | ≤100 | ≤100 |
Short-circuit breaking capacity level | M | H | M | H | M | H | M | H |
Rated limit short-circuit breaking capacity Icu (kA) | AC400V | 50 | 85 | 50 | 85 | 65 | 100 | 75 | 100 |
AC690V | 35 | 50 | 35 | 50 | 42 | 65 | 50 | 65 |
Rated operating short-circuit breaking capacity Ics (kA) | AC400V | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 20 |
AC690V | 10 | 10 | 10 | 10 | 15 | 15 | 15 | 15 |
Rated short-time withstand current Icw (kA/1s) | 1.5 | 3 | 5 | 10 |
Use category | A | A | B | B |
Compliance with standards | IEC60497-2/GB/T14048.2 |
Applicable working ambient temperature | -35°C~+70°C |
Electrical life (times) | 8000 | 8000 | 7500 | 7500 |
Mechanical life (times) | 20000 | 20000 | 10000 | 10000 |
Front panel connection | █ | █ | █ | █ |
Back panel connection | █ | █ | █ | █ |
Plug-in wiring | █ | █ | █ | █ |
Undervoltage release | █ | █ | █ | █ |
Shunt release | █ | █ | █ | █ |
Auxiliary contact | █ | █ | █ | █ |
Alarm contact | █ | █ | █ | █ |
Electric operating mechanism | █ | █ | █ | █ |
Manual operating mechanism | █ | █ | █ | █ |
Intelligent control module | █ | █ | █ | █ |
Test power module | █ | █ | █ | █ |
Communication function | █ | █ | █ | █ |
Time setting | █ | █ | █ | █ |
Samples & Structures Shape and installation dimensions
Company Profile
FAQ
Q: If I am interested in your MCB, when can I receive your quotation and details after sending the enquiry?
A: All your inquiries will be answered within 8 hours.
Q: Can I get samples before placing an order? Because I really don't know if your company's products are of good quality or not.
A: Certainly! We also believe that sample orders are the best way to prove quality. Welcome to inquire about the products you want
Q: What are your terms of trade?
A: We accept exw, fob, cif, fca, etc.
Q: How long is the delivery time?
A: Sample order usually takes 3-5 working days, formal order usually takes 10-20 days.
Q: how to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming,we'll make a satisfied solution for you whin 3 days· Power consumption is far below the national standard requirement
· High quality, withstand analysis
· Perfect appearance, feast for the eyes
· Longer mechanical and electrical life and better performance, greatly reducing maintenance costs for users
Address:
No. 555, Liule Road, Liushi Town, Wenzhou, Zhejiang, China
Business Type:
Manufacturer/Factory
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001
Company Introduction:
AnISO certified LV & HV electrical appliance manufacturer and global solutions supplier with first-class facilities and strong R&D strength, established in 1996, is one of the China TOP 500 Enterprises and World Machinery Top 500 Enterprises, which has 4 large scale manufacturing bases in Wenzhou (Zhejiang), Jiading (Shanghai), Nanchang (Jiangxi) and Fuzhou (Jiangxi), 12 wholly-owned subsidiaries, 85 holding members.
The products are populary sold to over 70 countries and regions, which are widely used in Pudong Airport, Beijing-Shanghai high-speed railway, Three Gorges Hydropower, Beijing Subway, South North Water Transfer, Qinghai-Tibet Railway, Chang′e Lunar Exploration Project and Vietnam Taian hydropower project etc. Major projects at home and abroad, which ranked among the World′s Top 500 Machinery Enterprises.
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.