• Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
  • Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
  • Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
  • Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical

Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical

Electricity Type: MCB
Number of Pole: 2p, 3p, 4p
Phase: 2/3/4
Samples:
US$ 3.01/Piece 1 Piece(Min.Order)
| Order Sample
standard packing
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical pictures & photos
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
US $0.1-3.01 / Piece
Min. Order: 1 Piece
Gold Member Since 2005

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RDX6-63
Main Circuit Rating Voltage
400V
Main Circuit Rating Current
up to 63A
Type
Mini Circuit Breaker
Frequency
50Hz, 60Hz
Standard
IEC/ En60898
Release Type
C, D
Transport Package
Export Standard Packing
Specification
Carton
Trademark
PEOPLE or OEM
Origin
Zhejiang, China
HS Code
8536200000
Production Capacity
70000 PCS/Per Month

Packaging & Delivery

Package Size
44.00cm * 24.00cm * 18.00cm
Package Gross Weight
14.000kg
Lead Time
20 days (1 - 100 Pieces)
To be negotiated ( > 100 Pieces)

Product Description

Product Description

 

RDX6-63 miniature circuit breaker is applicable to a circuit of AC50/60Hz, 230V (single phase), 400V (2, 3, 4 phases), for overload and short circuit protection. 
Rated current up to 63A. It also can be used as a switch for an infrequent conversion line. It is mainly used in domestic installation, as well as in commercial and industrial electrical distribution systems. It conforms with the standard of IEC/ EN60898.


Application

1.Temperature: The upper limit of surrounding air temperature should not exceed +40ºC, the lower limit should not be lower than -5ºC, and the 24h average temperature should not exceed +35ºC.
2.Altitude: The altitude of the installation site should not exceed 2000m.
3.Humidity: The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40ºC. Higher relative humidity can be allowed at lower temperatures. Special measures should be taken for condensation that occasionally occurs on the surface of the product due to temperature changes.
4.Pollution level: Grade 2.
5.Installation conditions: Installed in a place without significant shock and vibration, and in a medium without explosion hazard.
6.Installation method: Installed with TH35-7.5 mounting rail.
7.Installation category: Class II, III.




 Model No.
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical

Main technique parameter

The overcurrent release characteristics of the circuit breaker under normal installation conditions and reference ambient temperature (30-35)ºC are in accordance with the provisions of Table 1.
The main technical performance indicators of the circuit breaker are shown in Tables 1 and 2.
                  Table1
No. Tripping type  Rated current In  Test current A  Approximate time  Expected result  Starting state
1 C,D All values 1.13In t≤1h does not decouple cold state
2 C,D All values 1.45In t≤1h decouple immediately after the serial number 1 test
3 C,D ≤32A 2.55In 1s<t<60s decouple cold state
32A<In≤63A 1s<t<120s
4 C   5In t≤0.1s does not decouple cold state
D 10In
5 C All values 10In t≤0.1s decouple cold state
D 20In decouple
                  Table2
Tripping type Rated current A  Rated short-circuit breaking capacity A COSφ
C,D 1≤In≤63 10 000 0.45~0.50


Shape and installation dimensions

Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
Company Profile

 


Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People ElectricalMini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical
Mini Circuit Breaker Rdx6-63 Serise 230V/400V 10ka People Electrical

 
FAQ

1. What's your trading methods?

It's according to your request.

2.What's your Payment terms?

We accept kinds of payment terms,e.g.TT,L/C,O/A.

3.Would you accept to use our LOGO ?

If you have good quantity,it absolutely no problem to do OEM.

 
Any questions please feel free to contact us,we will reply you witin 8 hours.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now